Resetting Totals on RLM3:
Hit ESC until
you have the DIAG-> prompt.
- Press S for Security Code
- You are given an Access Code
(73)
- 100 minus the Access
Code, then reverse the digits to get the Security Code
- 100 - 73 = 27, so the
Security Code is 72
- At the DIAG (P)> prompt,
select D, then D again for the Data Base Section
- Press C to Clear, then answer
Yes to all three questions
- ESC out of the database until
you have the DIAG(P)-> prompt.
- Press <S> then <ESC> to leave the (P) mode